Bargain hunting · Winter shopping
Electric heater running costs: work out the bill before buying
A £90 heater does not automatically use less electricity than a £30 one. If two plug-in electric heaters consume the same kilowatt-hours on the same tariff, their electricity costs are the same. Compare what you pay to buy the heater with what you expect to spend using it.
By Tillio editorial · Sources checked
More on this purchase: Heating and winter comfort · Calculate the running cost
Calculate your purchase and electricity cost
Use your own tariff, power and time. Enter a delivered purchase price to include it in the estimate. The tool’s example inputs are illustrative.
Scope of this research
- This is desk research, with no hands-on product testing. The named reviewer is a fictional Tillio editorial voice.
- All monetary calculations are illustrative. No current tariff, measured duty cycle or guaranteed saving is asserted.
- The £30 and £90 heaters are hypothetical purchases, not retailer offers. Equal assumed electricity consumption does not establish equal comfort or measured performance.
Does a more expensive heater cost less to run?
The Centre for Sustainable Energy explains that electric room heaters turn all the electricity they use into heat at the point of use. Paying more for a ceramic element, oil-filled body or app does not, by itself, establish lower electricity use. This comparison is about ordinary direct electric heaters; a heat pump works differently.
Controls, the way warmth reaches you and whether the heater suits the space can affect the energy needed for a comfortable session. A lower wattage is a lower rate of consumption while operating, not proof of a lower total bill. Check the complete session and what you would use instead.
Sources: Centre for Sustainable Energy: room heaters · Energy Saving Trust: electric heating
Find your rate, then do one small calculation
Use the electricity unit rate shown on your tariff or recent bill, including VAT if the rate you are comparing includes VAT. Do not use the total bill divided by units, because standing charges and adjustments can distort that figure. On a time-of-use tariff, use the rate during the hours you plan to heat the room.
The arithmetic is: power in kilowatts multiplied by hours of operation multiplied by the price per kilowatt-hour. Divide watts by 1,000 first. A 2,000W heater becomes 2kW; 1,800W becomes 1.8kW. The result estimates the extra electricity used by the heater, rather than the household’s entire energy bill.
A simple cost-per-hour table
The rates below are illustrative inputs, not a claim about today’s price cap or your supplier. They assume a heater drawing the stated power continuously for one hour. Choose the column nearest your rate or calculate the exact number yourself.
| Heater draw | 20p/kWh example | 25p/kWh example | 30p/kWh example |
|---|---|---|---|
| 1kW | 20p/hour | 25p/hour | 30p/hour |
| 1.5kW | 30p/hour | 37.5p/hour | 45p/hour |
| 1.8kW | 36p/hour | 45p/hour | 54p/hour |
| 2kW | 40p/hour | 50p/hour | 60p/hour |
| 2.2kW | 44p/hour | 55p/hour | 66p/hour |
Compare the purchase price and the first month together
Illustrative comparison, not two actual offers: Heater A costs £30 delivered and Heater B costs £90 delivered. Assume both draw 2kW continuously for three hours on each of 20 days, at an example tariff of 25p/kWh. Each uses 120kWh and costs £30 in electricity. The dearer purchase is still £60 dearer after this use; the example does not assume equal comfort or predict either heater’s real cycling.
The same full-power routine on 30 days costs £45 in electricity. One half-hour session instead uses 1kWh and costs 25p; repeating that on 20 days costs £5. These are different amounts of heat bought, rather than an improvement in the heater’s efficiency.
| Illustrative cost | Heater A | Heater B |
|---|---|---|
| Purchase including delivery | £30 | £90 |
| Electricity: 120kWh at 25p/kWh | £30 | £30 |
| Purchase plus these 20 days | £60 | £120 |
A thermostat changes running time, not the unit price
The nameplate maximum is useful for an upper operating scenario, but a thermostatically controlled heater may cycle its heating element. The proportion of time drawing full power depends on the room, temperature target and conditions outside. It is not a fixed discount that can be copied from somebody else’s home.
Illustrative scenario: if a 2kW element actually heats for half of a three-hour session, its element consumption is 3kWh rather than 6kWh. At 25p/kWh that is 75p rather than £1.50, before any fan or standby consumption. Half-time operation is an assumption for this worked example; we have not measured it for a Tillio-listed heater.
Lower power settings can also change the draw. An appliance that spends twice as long at half the power can use roughly the same electricity. The useful comparison is the total energy needed for your comfort, not whether one setting feels less fierce.
Use real model numbers without borrowing a marketing promise
John Lewis rates the Duux Threesixty 2 UK model at 1800W. That becomes 45p for a continuous full-power hour at the illustrative 25p rate. Dimplex rates ThermaIQ DXBC22 at 2.2kW; the same scenario gives 55p. These are arithmetic examples using published maximum ratings, not measured operating costs.
There is no conclusion here that one warms your particular room for less. The two formats and controls differ. Comparing their headline “per hour” numbers while ignoring warmth, run time and purchase cost would produce a tidy table but a poor buying decision.
Sources: John Lewis: Duux Threesixty 2 DXCH09UK · Dimplex: ThermaIQ DXBC22
Do not count stored warmth twice
An oil-filled radiator can stay warm after its element switches off. De’Longhi explains that behaviour for its Radia S. The energy that later emerges from the oil went into it earlier; it is part of the same heating session.
When you compare a fan heater and a radiator, start and finish the accounting at sensible points. Counting the radiator’s cool-down as a free hour while excluding its warm-up gives it an artificial advantage. For a practical budget, use whole-session energy or a repeated daily total rather than a brief reading at one stage.
Sources: De’Longhi: Radia S TRRS0920E.G
Compare the alternative you would really use
Energy Saving Trust describes portable heating as secondary heating that can be useful for warming one room briefly, while warning that it can be expensive to run. That is a better starting point than a blanket claim that a portable heater always beats central heating.
Ask what you would switch on instead, which rooms need warmth, and whether the rest of the home still needs heating. A cheap individual heater may be useful during a short work session. Buying several to run for long periods is a different budget. Keep the household context in the calculation.
What would justify paying the extra £60?
To recover an extra £60 purely through electricity savings at 25p/kWh, a heater would have to use 240kWh less over your ownership period. Divide the extra purchase cost by your price per kWh to find your own break-even energy saving. If measured electricity use is the same, there is no electricity saving to repay the premium.
As an illustrative sensitivity check, a genuine reduction of 0.5kWh per use-day would save 12.5p at that example tariff and take 480 use-days to recover £60. We have not measured that reduction for either heater. You can still value easier controls or a different format; give that benefit an honest reason rather than inventing a payback.
Set a monthly allowance as well as a purchase budget
Write down your tariff, planned sessions and a monthly heating allowance before buying. In the illustrative £1.50-a-day case, a £30 allowance covers 20 such sessions. That makes it easier to decide whether a timer, easy-to-read thermostat or different routine would be genuinely useful.
Compare complete purchase totals using Tillio’s effective-price guide, and use the checkout checklist for delivery and voucher conditions. Save a target for the exact heater where alerts are available. Reducing a £70 purchase by £10 is welcome; it does not compensate for an operating pattern you cannot comfortably afford.
Sources and method
Prepared with AI-assisted desk research and checked against the linked primary sources. Retailer terms can change; read the current terms for your exact order. Read our checking and editorial method.